Showing posts with label subslab. Show all posts
Showing posts with label subslab. Show all posts
Tuesday, May 22, 2012
Cox-Colvin Presentations at Ohio Brownfield Conference on Thursday, May 24
Thursday, May 24th, will be a busy day for Cox-Colvin at the 2012 Ohio Brownfield Conference at the Columbus Convention Center. At 10:10 am in Room E170, Mort Schmidt will be talking about "Rapid Sub-Slab Soil Gas Sampling for Finding Sources". In the same room at 1:55 pm, George Colvin will be discussing "Use of an Alternate Regulatory Mechanism and Results-Based Approaches for Site Cleanup". Also, visit Cox-Colvin at Booth 18!
Friday, April 20, 2012
EPA Releases Vapor Intrusion FAQs
EPA recently posted Vapor Intrusion FAQs (frequently asked questions) on its Vapor Intrusion (VI) website. This 56-page document is much more than the average fact sheet, and provides a preview of what the much anticipated final VI guidance is likely to look like.
Read More>>
Labels:
Johnson Ettinger,
soil gas,
soil-gas,
sub-slab,
subslab,
vapor intrusion
Tuesday, April 17, 2012
Cox-Colvin to present on Innovative Subslab Soil-Gas Sampling Methods
Cox-Colvin employee Mort Schmidt will be presenting at A&WMA's 'Air Quality Measurement Methods and Technology' Conference to be held April 24 - 26, 2012 in Durham, North Carolina. Mort will be presenting his talk, entitled "Innovative Sampling Methods for Focusing the Subslab Soil-Gas Investigation" on Wednesday, April 25th @ 2:45 pm (Session 7A). Mort's presentation will highlight an investigation in which Cox-Colvin installed and sampled 145 sub-slab soil gas sampling points in five days to locate a source of tetrachloroethene at a manufacturing facility.
Cox-Colvin also will be exhibiting the Vapor Pin at the conference. Join us at Booth #19 to learn more about the Vapor Pin - a re-usable sub slab vapor sampling device.
Cox-Colvin also will be exhibiting the Vapor Pin at the conference. Join us at Booth #19 to learn more about the Vapor Pin - a re-usable sub slab vapor sampling device.
Wednesday, April 4, 2012
Short-listing Vapor Intrusion Constituents: Not Always A Good Idea
Many Vapor Intrusion guidance documents encourage analyzing a short list of comhttp://www.blogger.com/img/blank.gifpounds in indoor air -- for example, instructing the lab to report only the compounds detected in subsurface samples during previous related investigations. But be careful! As vapor intrusion assessment moves toward indoor air sampling, analyzing only for a short list of compounds could come back to bite you.
Read More >>
Read More >>
Labels:
constituents of concern,
indoor ai,
soil gas,
subslab,
vapor intrusion,
Vapor Pin
Tuesday, March 13, 2012
Another Vapor Pin Application - Measuring Subslab Pressures
A common approach for evaluating the radius of influence of a sub-slab vapor intrusion remediation system is to measure pressure differentials between the sub-slab and indoor air. With the Vapor Pin, more pressure monitoring points can be installed in less time and at a lower cost. This results in a better understanding of the effectiveness of the remedial system.
Read More>>
Read More>>
Monday, November 21, 2011
Cox-Colvin Presented on Soil-Gas Prospecting at AIPG Meeting
I presented a talk in September 2011 at the American Institute of Professional Geologists (AIPG) National Meeting in Bloomingdale, Illinois titled "The Use of Innovative Soil-Gas Sampling Methods to Locate VOC Sources". The presentation, which discussed how Cox-Colvin used the Vapor Pin to collect soil gas from beneath the floor of a large industrial facility to locate sources of volatile organic compound (VOC) contamination, was very well received. The use of the Vapor Pin, combined with collecting soil gas into disposable, evacuated glass vials, allowed us to collect approximately 240 samples over the entire building footprint in one week, using only hand-held equipment.
As we've seen at other sites, VOC contamination at this site was not located beneath former degreasing operations or storage tanks. Instead, using aerial photos and historic maps to reconstruct the building's history, we found that the contamination was located where loading docks and back doors used to be prior to building expansion. Before the Clean Water Act in 1977, it was accepted practice to dump used solvents on the ground - commonly through the nearest door. By now it's unlikely that any present employees remember dumping of waste, or would be comfortable discussing it if they did. But by sampling subslab soil gas in a grid over the entire building, and tying the analytical results to the building expansion history, we located an unsuspected source of VOCs and determined that it probably resulted from spillage or dumping prior to 1952. Better yet, the sample points were installed, sampled, and plugged each day at minimal cost and without interrupting plant operations. And when we're done locating sources, the soil-gas data will be useful for assessing vapor intrusion.
As we've seen at other sites, VOC contamination at this site was not located beneath former degreasing operations or storage tanks. Instead, using aerial photos and historic maps to reconstruct the building's history, we found that the contamination was located where loading docks and back doors used to be prior to building expansion. Before the Clean Water Act in 1977, it was accepted practice to dump used solvents on the ground - commonly through the nearest door. By now it's unlikely that any present employees remember dumping of waste, or would be comfortable discussing it if they did. But by sampling subslab soil gas in a grid over the entire building, and tying the analytical results to the building expansion history, we located an unsuspected source of VOCs and determined that it probably resulted from spillage or dumping prior to 1952. Better yet, the sample points were installed, sampled, and plugged each day at minimal cost and without interrupting plant operations. And when we're done locating sources, the soil-gas data will be useful for assessing vapor intrusion.
Labels:
AIGP,
chlorinated solvents,
forensic,
soil gas,
source,
subslab,
Vapor Intrusion Sampling,
VOC
Subscribe to:
Posts (Atom)